Have you ever met when you touch the iPhone
6 screen , but it is entirely no response, just like frozen. It cause big problems
on your daily life, but you have no idea what to do. Don't worry it, Vipprogtell you what to do
First, power on the iPhone and test it,
finding the touch function is completely lost. After replacing a display screen,
the result is the same. Remove the motherboard and observe, finding little
soldering paste around touch process chip, which suggests touch control chip
and touch process chip have been welded, as shown in picture 1-1.
1-1
Then,
using the multimeter to measure
the diode data of two ends of coupling capacitor (picture 1-2) that is used to
communicate between touch control chip and touch process chip. The data is
normal. One end of coupling capacitor near touch control chip is connected to
touch control chip, while the other end of coupling capacitor near touch
process chip is connected to touch process chip.
1-2
Next, measure the power supply voltage of PN5V7_SAGE_AVDDH,
PP5V7_SAGE_AVDDH, PP5V1_GRAPE_VDDH and PP1V8_GRAPE. The relevant circuit diagram is shown in picture 1-3 and 1-4.And we can found that touch control chip ‘s PP5V1_GRAPE_VDDH and
PP1V8_GRAPE have no voltage, which suggests there is abnormal communication
between CPU and touch control chip.
Generally, the damage of touch control chip or abnormal weld and the SPI bus,
clock and reset between touch control chip and CPU. Measuring points are the
yellow points shown in picture 1-5.
1-3
1-4
1-5
After measuring, the diode data of these
points is normal, so there is no problem in communication bus circuit between
CPU and touch control chip. Then power on again to test the 32kHz crystal
oscillator, finding no voltage. If 32kHz crystal oscillator is normal, there
should be 0.9v voltage. The pins of 32kHz crystal oscillator are shown in
picture 1-6.
1-6
The material object is shown in picture 1-7.
1-7
The function of 32kHz crystal oscillator is
to send its frequency to main power chip.
Then main power chip sends its clock signal to CPU. After receiving the clock
signal from main power chip, CPU sends it to touch control chip clock signal.
Find the clock pin of touch control chip and measure the diode data. The data
is normal. Therefore, CPU has no problem. The damage of 32kHz crystal
oscillator and the faulty chips that use 32kHz clock will cause the abnormal of
32 kHz clock, especially the Wi-Fi parts. The Wi-Fi chip’s material object is
shown in picture 1-8.
1-8
Finally, replace crystal oscillator and
power chip first, finding the problem is still the same. Then remove WiFi chip and measure. Now the 32 kHz clock has
0.9v voltage. After assemble touch control chip, the touch function becomes
normal. The iPhone 6 can back to normal work.